Main distribution boards for commercial building electrical rooms
Quantity: 1 lot
Including incoming ACB panels, outgoing feeder panels, metering, busbar system and auxiliary control wiring.
A low voltage switchgear and indoor transformer package supplied for a commercial building project in the United Arab Emirates, including MDB panels, feeder coordination, consultant documentation, testing records and shipment support.
A low voltage switchgear and indoor transformer package supplied for a commercial building project in the United Arab Emirates, including MDB panels, feeder coordination, consultant documentation, testing records and shipment support.
This project involved the supply of low voltage switchgear and indoor transformer equipment for a commercial building power distribution system in the United Arab Emirates. The supplied scope supported main incoming distribution, outgoing floor feeders, auxiliary loads and building electrical room installation.
Before production, the consultant specification, panel schedule and single-line diagram were reviewed to confirm main busbar rating, short-circuit withstand level, incoming protection, outgoing feeder layout, metering requirements, form of separation and cable entry arrangement.
The panels and transformer equipment were manufactured and tested with the required technical documents, drawings and inspection records before shipment.
Send us your single line diagram and ratings. You get a matched proposal, drawings, and a delivery plan within 24 hours.
Every unit delivered for this project, with quantity and configuration notes.
Quantity: 1 lot
Including incoming ACB panels, outgoing feeder panels, metering, busbar system and auxiliary control wiring.
Quantity: 2 units
Supplied with indoor enclosure, temperature monitoring and project documentation.
Quantity: 1 lot
Configured according to the building electrical load schedule and consultant requirements.
Tell us your voltage, capacity, and quantity. We confirm configuration, accessories, and lead time for your order.
Voltage, capacity, and protection parameters confirmed for this project.
| Parameter | Value | Notes |
|---|---|---|
| Transformer Capacity | 1600 kVA | Per transformer |
| Primary Voltage | 11 kV | Medium voltage side |
| Secondary Voltage | 0.415 kV | Low voltage side |
| Frequency | 50 Hz | According to project requirement |
| Transformer Type | Cast resin dry type | Indoor commercial building installation |
| LV Switchgear Rated Voltage | 415 V | Building low voltage system |
| Main Busbar Rating | 4000 A | Main distribution board rating |
| Short-circuit Current | 50 kA / 1s | According to consultant specification |
| Form of Separation | Form 4b | Confirmed during approval stage |
| Incoming Protection | ACB | With metering and protection accessories |
| Metering | Multifunction meters | Prepared according to panel schedule |
| Enclosure Protection | IP42 | Indoor electrical room installation |
| Cable Entry | Top and bottom entry | Confirmed according to site layout |
Share your project specification and we map every parameter, vector group, and impedance to your requirement before production.
The requirement on site, and how the specification, drawings, and production were supported.
<p>The commercial building project required switchgear panels to match the consultant specification, panel schedule and limited electrical room layout. The main concerns included main busbar rating, short-circuit level, form of separation, metering arrangement, outgoing feeder identification, cable entry direction, installation clearance and approval document submission.</p>
Our engineering team reviewed the consultant specification, SLD, panel schedule and electrical room layout before preparing the switchgear proposal. The MDB arrangement, busbar rating, incoming protection, outgoing feeder schedule, metering configuration, dry type transformer scope and cable entry direction were checked before production.
We prepared a coordinated technical document package with datasheets, arrangement drawings, wiring references, compliance statement, FAT procedure and test reports to support consultant review and site installation.
Our engineers review your drawings, deviations, and standards so your equipment clears consultant and utility approval the first time.
Inspection items and engineering documents prepared for this project.
<p>Factory inspection covered panel dimensions, busbar arrangement, protection device installation, mechanical operation, interlock checks, secondary wiring, insulation resistance and power frequency withstand voltage. Dry type transformer routine tests and temperature controller checks were completed before shipment.</p>
We arrange routine tests, witness inspection, and full document sets so your equipment ships with proof of compliance.
Production, testing, and finished equipment from this project.
You get progress photos at production, testing, and packing stages so you track your order from factory to container.
Export packing, container loading, and nameplate records for this shipment.
Send your destination port and timeline. We handle export packing, loading, and documents so your equipment arrives ready to install.